Tempe, Arizona Fire Codes And How They Pertain To Exit Devices

The city of Tempe, Arizona has recently amended some of its fire codes regulations to enable them to be at par with the 2006 international fire code laws. Specifically, when it comes to the new Tempe, Arizona fire codes and how they pertain to exit devices, below are some of the most notable amendments which have been enacted, thanks to tempelocksmithpros.com.

Door, gates and turnstiles

The whole of section 1008 of the new city of Tempe fire codes primarily dwell on the recommended features and functions of exit doors, gate and turnstiles. To begin with, a floor elevation is mandatorily on either side of the exit door, both featuring a similar elevation height. Nonetheless, there are several exceptions to this guideline. For instance, exit doors that serve dwelling units in group R-1 and R-2 buildings (hotels and residential units with 2 sleeping units respectively) are not affected by this law.

In such buildings, an exit door is allowed to open at the topmost step of an interior flight of stairs. That is as long as this exit door can swing easily over the topmost step of such a flight of stairs. Additionally, in such buildings, storm door and screen doors are also permissible if they can swing over the stairs or landing. Houses with external decks, patios or even balconies are also excluded from this given guideline of the Tempe, Arizona fire codes rule. Most especially if they are features of a type B (lowest building fire hazard level). In such units, an impervious surface, which is less than 4” beneath the finished floor level of an adjacent interior area is allowable. That is as long as the exit door (excluding storm or screen doors) doesn’t swing over the landing when opened.

Locks and latches

exit bar installingSection 1008. of the new city of Tempe, Arizona fire codes dwells on the locks and latches that can be equipped to exit devices. According to this regulation, locks and latches are permissible when they can be in a position of preventing the operations of such devices in the following circumstances. First of all, buildings that are used for correction or detention of convicts such as jails or penitentiaries. Buildings which are categorized as occupancy group A (moderate fire hazard level) with occupancy of three hundred or below. Group B, F, M and S (moderate to lowest risk of fire hazards) and also places of worship like churches. In the latter category, these kinds of building are allowed by the new guidelines to be fitted with key lockable exit devices, which are positioned on the egress side.

On the other hand, in the cases where egress doors happen to be utilized in pairs, approved automatic flush bolts are also permissible. That is as long as the given door leaf that bears the automatic flush bolts does not come with a door knob or any surface mounted hardware.

At the same time, group R, division 3 occupancy as well as individual dwelling units and guestrooms are also mentioned by the new Tempe, Arizona fire codes. The exit doors of these given buildings are now required by the law to be fitted with night latches, keyed deadbolts or even security chains. The only stipulation for equipping the exit doors with these devices is that they can be conveniently from the interior part of the building without having to use a tool.

Finally, the section 1008 of the amended Tempe city fire codes has now made it mandatory for an easily readable and durable signage to be posted on the egress side close to the exit doors. Such a sign must clearly state “This door is to remain unlocked whenever this building is occupied.”

Exit discharge

exit device3The section 1024 of the amended city of Tempe, Arizona fire codes, for the most part, offers guidelines on the right exit discharges building ought to have. Such exit discharges should offer a direct and unobstructed access to a public way. In the event where this is not possible, a safe dispersal region must be allocated on such properties.

This dispersal region should be able to accommodate not less than five square feet for each individual in the event of a fire outbreak. At the same time, it should also be located within the same property, and not more than fifty feet away from the building, which might need egress. Finally, such a dispersal region should come with a safe and unobstructed path from the building in question.

Share

Understanding Exit Devices

Most buildings all over the world are inspected yearly to ensure that they comply with the set standards in terms of safety and more. After thorough inspection, fire department provides you with a full report to help you make the necessary corrections if any. However, such inspections vary from one state to the other and therefore it is essential to understand the fire codes of your state before you commence your construction. Note that codes remind you of the things that should be met and the kind of exit devices, fire-alarm system, and fire sprinkler system to be installed.
Before you install the above systems, it is prudent to involve a specialist who understands how to install the needed systems properly.
Resources:
www.tigardlocksmith.org
grainger.com
homedepot.com

Exit Devices

They are also known as panic device, push bar or panic bar. These devices are used for unlocking the door during emergency situations. Today, each and every building should comply with the building codes, which make sure that every public building has at least one exit device. Fortunately, crash bar can be installed in a wide range of door types as a way to save lives in the event of fire, stampedes, terrorism attack and more. It has been found that panic can occur in situations of fire or explosions making the rescue process a bit tricky, but with exit devices, evacuations will be far much easy.

A door designated for exit does not have a handle on the outside. This feature makes sure that your home is secure. However, some doors meant for exit have been fitted with handles on the outside and inside as well. Such doors can be opened freely from either side allowing occupants to enter or exit the building with a lot of easy.

Factors to Consider when Installing Panic Devices

Ease of Installation

Commercial locksmith3Always choose the panic bars that are easy to install, repair and inexpensive to replace. For instance, a crossbar rim device the easiest to assemble. If you do not like crossbar, you may consider using push pad rim device, which is also the simplest to work with and needs no or little maintenance. Pad rim devices are suitable for buildings with high-traffic.

Safety

When installing an exit device, you should bear in mind the safety of your loved ones. A good panic device should comply with ANSI Grade 1 standards. In other words, devices should be designed in such a way that they can tolerate forced entry.

Available Options

Panic devices come in a wide range of options. As a result, you should choose the option that suits your safety needs. Many people prefer using cross bar devices due to the fact they offer incredible architectural finishing as well as available in a variety of colors.

Applications of Exit Devices

In general, panic bars are commonly used in care centers, learning institutions, retail stores, hospitals offices and more. These devices play a role in ensuring that the work place is secure and safe.

Types

The common types include: multi-point, rim, cable, touchpad, recessed, crossbar and mortise exit devices respectively. All these types comply with building codes while enhancing the safety of your property. In addition, they match different door types since they come in different shapes and colors.

Fire Codes

Fire CodesFire safety codes complement the building code. Generally, fire codes play an important role in preventing fires and make sure that the original plan of a structure is not compromised at all. These codes vary from state to state.
To comply with life safety codes, you should install exit devices in particular cases. These codes forbid the use of locks that may confuse or compromise the safety of the user. To enhance safety, fire devices should be self-latching in event of fire. Apart from being self-latching, fire doors should be able to close to prevent fire from spreading.
In most households, security, life safety and fire can be a day-to-day challenge. Some homeowners view security as a major concern and therefore end up securing their homes with unauthorized locks, which may pose risks to users in case of an emergency. It is advisable to go for an option that satisfies both concerns: life safety and security. Feel free to talk to fire inspector to help you through exit devices and their fire codes, so as to make an informed decision at the end of the day. This way, you will be able to make your home safe and secure for all.